Shenyang Jinyan Laser has recently repaired the guide vane of the air compressor, the air compressor intake regulator. .
Our company first cleans the guide vane and repairs the defects, and then uses advanced repair technology to repair the guide vane. No other defects are found after coloring inspection. Afterwards, it was refined according to the original size, and after the size inspection, it was consistent with the original size, and the repair was successful.
Knowledge points:
The air compressor is one of the main mechanical power equipment of many enterprises, and it is very necessary to maintain the safe operation of the air compressor. Strictly implementing the air compressor operating procedures will not only help prolong the service life of the air compressor, but also ensure the safety of the air compressor operators. Let's take a look at the air compressor operating procedures.
1. Before operating the air compressor, you should pay attention to the following issues:
1. Keep the lubricating oil in the oil pool within the range of the scale. Before operating the air compressor, check that the amount of oil in the oiler should not be lower than the scale line value.
2. Check whether each moving part is flexible, whether each connecting part is tight, whether the lubrication system is normal, and whether the motor and electrical control equipment are safe and reliable.
3. Before operating the air compressor, check whether the protective devices and safety accessories are in good condition.
4. Check that the exhaust line is unobstructed.
5. Connect the water source, open each water inlet valve, and make the cooling water unblocked.
2. When operating the air compressor, it should be noted that before starting for the first time after long-term deactivation, it must be checked by cranking, and pay attention to whether there is any phenomenon such as collision, jamming or abnormal noise.
3. The machine must be started in a no-load state. After the no-load operation is normal, the air compressor will gradually enter the load operation.
Fourth, when the air compressor is operating, after normal operation, you should always pay attention to the readings of various instruments and adjust them at any time.
5. During the operation of the air compressor, the following conditions should also be checked:
1. Whether the temperature of the motor is normal, and whether the readings of each meter are within the specified range.
2. Whether the sound of each machine is normal.
3. Whether the suction valve cover is hot, and whether the sound of the valve is normal.
4. Whether the various safety protection equipment of the air compressor is reliable.
6. After the air compressor is operated for 2 hours, the oil and water in the oil-water separator, the intercooler and the after-cooler shall be discharged once, and the oil and water in the air storage tank shall be discharged once per shift.
7. When the following situations are found in the operation of the air compressor, it should be stopped immediately, the reasons should be found out and eliminated.
1. The lubricating oil is interrupted or the cooling water is interrupted.
2. A sudden rise or fall in water temperature.
3. The exhaust pressure suddenly rises and the safety valve fails.
The operation power part of the compressor must comply with the relevant regulations of the internal combustion engine.
The above content comes from the Internet, invaded and deleted